Differences between revisions 10 and 19 (spanning 9 versions)
Revision 10 as of 2013-06-24 16:55:29
Size: 2946
Comment:
Revision 19 as of 2013-09-25 16:34:51
Size: 3043
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
= Reducing Bath Fill Noise = ## page was renamed from BathNoise
Bathtub Muffler
=
= Reducing Bath Fill Noise ==
Line 11: Line 13:
'''Wrap the end of the faucet in a washcloth, so that a "pipe" of washcloth hangs down into the water. Secure with rubber bands.''' '''Wrap the end of the faucet spout with a washcloth, so that a "pipe" of washcloth hangs down into the water. Secure with rubber bands.'''
Line 25: Line 27:
Optimization might include some kind of outdoor sunshine drying fixture for the summer, and an indoor humidifier drying fixture for the winter, but I've got other things to do! ||{{attachment:faucet.jpg|faucet with washcloth wrap|width=400}}||Faucet running full blast, quietly. [[attachment:faucet.jpg|1600x1200 picture]]||
Line 27: Line 29:
== A note about David Friedman's refill valve problem == === A note about David Friedman's refill valve problem ===
Line 29: Line 31:
If not for the mildew problem, a tap off the main faucet to a valve at the head end of the tub feeding a meter of garden soaker hose might be even quieter, and solve the "controls in the wrong place" problem. I bet DDF could figure out a way to keep the hose clean, and pay a plumber $500 to add the extra piping and valves. The extra pipe should run in the cavity between the wall and tub, with heat-reflecting foil on the wall, so the cooling pipe heats the tub anyway. For extra bonus points, put an inline heater on this pipe, and for safety add a foot of electrically-insulating plastic pipe between the heated pipe and the electrically-grounded new valve. Since the new valve will get used a lot, hunt for a design that doesn't need washers changed every 6 months. A tap off the main faucet to a valve at the head end of the tub feeding a meter of garden soaker hose might be even quieter, and solve the "controls in the wrong place" problem (there could be mildew problems, though). I bet DDF could figure out a way to keep the hose clean, and pay a plumber $500 to add the extra piping and valves. The extra pipe should run in the cavity between the wall and tub, with heat-reflecting foil on the wall, so the cooling pipe heats the tub anyway. For extra bonus points, put an inline heater on this pipe, and for safety add a foot of electrically-insulating plastic pipe between the heated pipe and the electrically-grounded new valve. Since the new valve will get used a lot, hunt for a design that doesn't need washers changed every 6 months.
Line 31: Line 33:
Alternate to this alternative, a foot pedal valve at the faucet end? They make such valves for surgeon sinks and emergency showers. Alternate to this alternative, a foot pedal valve from the hot incoming pipe to a soaker hose spout at the faucet end? They make such valves for surgeon sinks and emergency showers.

Bathtub Muffler

Reducing Bath Fill Noise

Like David D. Friedman, I take long baths and read. I need quiet time before bed in order to sleep, and a long hot bath with a non-threatening book works well for this (calculus is the best soporific!). Yes, it costs water and energy, but I live in Oregon, with more water and energy than most places.

But the noise of the occasional hot water refill interferes with my wife's sleep, who goes to bed before I do (reread "quiet time" sentence above).


A trick that reduces the noise:

Wrap the end of the faucet spout with a washcloth, so that a "pipe" of washcloth hangs down into the water. Secure with rubber bands.

The washcloth slows fill rate a bit, but it also eliminates most of the noise. It does this five ways:

  • 1) The washcloth slows down the falling water, which longer hammers the tubwater surface.
  • 2) The point of impact is muffled.
  • 3) The cavitation and noise of the falling water goes away.
  • 4) The resonance of the faucet spout itself is dampened.
  • 5) This will reduce water hammer in older houses with poorly-secured pipes.

This also allows turning off the faucet handles with toes without risk of feet veering into a scalding hot stream.

Yes, this uses up washcloths (you want to change them or they will mildew). But if yesterday's scrub washcloth becomes today's sound reduction washcloth, then tomorrow's hang-out-to-dry before laundering washcloth, you've merely added one "wet day" on the way to the laundry hamper. I usually dry them for two days so they are bone dry before they go in the hamper, and have a repurposed towel rack under a cabinet for the purpose.

faucet with washcloth wrap

Faucet running full blast, quietly. 1600x1200 picture

A note about David Friedman's refill valve problem

A tap off the main faucet to a valve at the head end of the tub feeding a meter of garden soaker hose might be even quieter, and solve the "controls in the wrong place" problem (there could be mildew problems, though). I bet DDF could figure out a way to keep the hose clean, and pay a plumber $500 to add the extra piping and valves. The extra pipe should run in the cavity between the wall and tub, with heat-reflecting foil on the wall, so the cooling pipe heats the tub anyway. For extra bonus points, put an inline heater on this pipe, and for safety add a foot of electrically-insulating plastic pipe between the heated pipe and the electrically-grounded new valve. Since the new valve will get used a lot, hunt for a design that doesn't need washers changed every 6 months.

Alternate to this alternative, a foot pedal valve from the hot incoming pipe to a soaker hose spout at the faucet end? They make such valves for surgeon sinks and emergency showers.

BathtubMuffler (last edited 2013-09-25 16:34:51 by KeithLofstrom)